The Structural Engineer > Archive > Volume 74 (1996) > Issues > Issue 11 > Dynamic Testing and Numerical Modelling of the Cardington Steel Framed Building from Construction to
Name of File 5979-74-11.pdf cached at 14/12/2017 02:27:32 - with 7 pages. pdfPath: E:\k9.istructe.org\CMS\webtest\files\6c\6c0e7572-1d3a-4821-97c1-382999ab017e.pdf. thumbPath: E:\k9.istructe.org\CMS\webtest\files\pdfthumbs\6c0e7572-1d3a-4821-97c1-382999ab017e_1.png. objDoc: 1 - True. objPreview.Log: . strFileName: 6c0e7572-1d3a-4821-97c1-382999ab017e_1.png

Members/subscribers must be logged in to view this article

Dynamic Testing and Numerical Modelling of the Cardington Steel Framed Building from Construction to Completion

This paper is concerned with the dynamic behaviour of an eight-storey steel-framed building. The building construction was undertaken in discrete stages, five of which are described. At each stage the natural frequencies of the building were measured using a laser system. A comprehensive forced vibration test was also performed when the building was complete to determine all of the characteristics of the fundamental modes of vibration. Both types of test are described, and the results that were obtained are presented. In parallel with the dynamic tests, numerical modelling has been conducted at each stage. The finite element model is described, and the main calculated results are presented. The measurements and calculations are then compared to provide a better understanding of the building behaviour and to identify where the numerical model needs to be improved. Finally, the benefits from the combined experimental and numerical studies are discussed. B.R. Ellis and T. Ji

Author(s): Ellis, B R;Ji, T

Keywords: steel;frames;tests;fires;dynamic loads;floors;walls;effects;comparing;modelling;measuring;multistorey buildings;vibration;experimental methods