Name of File 2886-83-10.pdf cached at 15/12/2017 17:54:26 - with 5 pages. pdfPath: E:\k9.istructe.org\CMS\webtest\files\67\67e3008a-f4b7-424f-b169-53e5087e5ca2.pdf. thumbPath: E:\k9.istructe.org\CMS\webtest\files\pdfthumbs\67e3008a-f4b7-424f-b169-53e5087e5ca2_1.png. objDoc: 1 - True. objPreview.Log: . strFileName: 67e3008a-f4b7-424f-b169-53e5087e5ca2_1.png

Members/subscribers must be logged in to view this article

Steel channel and hollow block floor slabs

The domestic and light industrial floor market in South Africa comprises a floor system referred to as the rib and block floor slab. The floor system is a concrete composite, composed of in situ concrete, precast ribs and hollow block void formers. The system is noted for its speed of construction and formwork is not required. However, transportation costs of the precast ribs and the need for lifting equipment renders the system uneconomical beyond a limited radius from the factory. To minimise costs, a new system is proposed, which replaces the precast rib with a cold-formed lipped channel. A set of design equations, adapted from the code, are compared with a set of experiments. The investigation indicated the proposed system is a viable alternative, but embossment or means to mechanically bond the concrete to the steel is required to achieve composite action. M. Gohnert, BSc, MEM, PhD, CEng, Pr Eng, AIStructE University of the Witwatersrand, South Africa M. J. Komakec, BSc, GDE, MSc University of the Witwatersrand, South Africa

Author(s): Gohnert, M;Komakec, M J

Keywords: rib and block floor system;floors;south africa;design;sabs0100;bs8110;shear;bonding;experiments