In this paper the assumptions made in the existing methods of analysis of pitched roof frames are discussed. A general elastic-plastic analysis is then presented taking full account of instability due to joint translations as well as member curvature. An electronic digital computer programme to do the analysis is outlined and charts prepared using the analysis are given so that they may be used directly in the design of such frames. K.I. Majid

Additional information

Format:
PDF
Publisher:
The Institution of Structural Engineers

Tags

Issue 5

Related Resources & Events

The Structural Engineer
The Design of Two Unusual Structures at York University

The Design of Two Unusual Structures at York University

This paper describes the design and construction of a tall chimney and a water-tower for the University of York. Both structures are of reinforced concrete and involve unusual proportions and shapes which are potentially susceptible to wind-induced vibrations. During the design stage their behaviour was fully investigated by testing models in a wind tunnel. Observations were made both of the static wind pressures on the models and of the unsteady wind effects upon them. For the latter observations models were constructed to reproduce to the appropriate scales the dynamic properties of the structures. The range of the experiments included the influence of the liquid contents of the water-tower and the effect of the high structural damping inherent in reinforced concrete. Measurements of the structural damping that were made on the completed chimney structure gave values of the logarithmic decrement in the range 0 075 to 0.115. It was concluded that the high structural damping was an important factor in ensuring the stability of the chimney. G.M.J. Williams, Professor D.S. Houghton and G.M. Moss

Author - Williams, G M J;Houghton, D S;Moss, G M
Price - £9
The Structural Engineer
The Fatigue Strength of Wrought Iron after Weathering in Service

The Fatigue Strength of Wrought Iron after Weathering in Service

The wrought iron which was the subject of this investigation was taken from Brunel's tubular bridge at Chepstow during its demolition in 1962, after 110 years of service. M.S.G. Cullimore