The author's experience on several codes-of-practice committees has led him to the conclusion that one of the greatest fields of uncertainty lies in the specifying of effective lengths of continuous columns. This is coincidental with the difficulty of calculating elastic critical load factors and dealing with frame instability. Comprehensive design charts are given for effective lengths of columns with any local degree of end restraint, both for sway and no sway conditions. To design for the limit-state of collapse it is essential to discover new 'desk' methods of dealing with overall frame instability when effective lengths based on local restraints are not accurate enough. A new technique of 'stiffness distribution', akin to moment distribution, will be acceptable in a drawing office, both for steel and reinforced concrete frames, at the same time providing rapid estimates of the other limit-state of permissible sidesway. Important modifications for strain hardening and composite panel stiffening are included, indicating the urgent need for more full-scale tests on composite action with cladding. The emphasis throughout has been on simplicity of theory and of the many worked examples. R.H. Wood

Additional information

Format:
PDF
Publisher:
The Institution of Structural Engineers

Tags

Issue 9

Related Resources & Events

The Structural Engineer
The President 1974-75

The President 1974-75

Mr. Derek R. R. Dick, BSc, CEng, FIStructE, FICE, will take office as President of the and at an Ordinary Meeting at 11 Upper Institution 1974-75 on 3 October next evening will deliver his Presidential Address Belgrave Street, London at 6.0 pm that 'The Future of the Institution'.

Price - £9
The Structural Engineer
Discussion on Blow, Blow, thou Winter Wind, th'art Not so Unkind as Chap. V:  Part 2 by Ronald G. Ta

Discussion on Blow, Blow, thou Winter Wind, th'art Not so Unkind as Chap. V: Part 2 by Ronald G. Ta

Professor S. Mackey (F) : My main concern is to learn why, in Britain, limited records of wind and pressure measurements are being extrapolated to such a degree that if applied to Hong Kong conditions would render economic design of buildings impossible.

Price - £9
The Structural Engineer
Discussion on Prestressing Steels by K.W. Longbottom and G.P. Mallett

Discussion on Prestressing Steels by K.W. Longbottom and G.P. Mallett

Mr. B. Rhodes: Mr. Longbottom has done less than justice to large diameter strand, by which I mean 28 mm (1 1/8 in) diameter strand. I know it is not used a lot, but this is really because of lack of effort on the part of the manufacturers and the system suppliers. 28 mm diameter strand has certain basic drawbacks, namely: 1. The shape of the load/extension curve 2. Relaxation losses at 6 per cent 3. Lower grip efficiencies 4. The tendency to fly open when cut 5. The 'banana' effect at the ends