Limit State Design of Pin-jointed Space Structures
Date published

N/A

Price

Standard: £10 + VAT
Members/Subscribers: Free

Back to Previous

Limit State Design of Pin-jointed Space Structures

Tag
Author
Date published
N/A
Price

Standard: £10 + VAT
Members/Subscribers: Free

The Structural Engineer
Citation

The Structural Engineer, Volume 60, Issue 13, 1982

Date published

N/A

Citation

The Structural Engineer, Volume 60, Issue 13, 1982

Price

Standard: £10 + VAT
Members/Subscribers: Free

Slender space structures covering large areas can suffer from excessive deflections. In this paper a simple but exact method is given for the design of such structures. This calculates the cross-sectional areas of members so that recent limit state design requirements for strength, well as deflections, are fully satisfied. The method does not depend on analysis of the structure with preselected sections and thus removes need for the explicit solution of a large number of simultaneous stiffness equations. In this manner it saves considerable computer time. Instead proportions the members in the most economic manner and calculates their unknown areas. A design procedure is given so that all the recent BSI recommendations for the limit state design of steel structures satisfied. The results of an investigation into the design of space structures are then reported, in conjunction with a number of practical examples.

K.I. Majid and S.Okdeh

Additional information

Format:
PDF
Publisher:
The Institution of Structural Engineers

Tags

Issue 13

Related Resources & Events

The Structural Engineer
<h4>The Effects of Elevated Temperatures on the Strength Properties of Reinforcing and Prestressing Stee</h4>

The Effects of Elevated Temperatures on the Strength Properties of Reinforcing and Prestressing Stee

The effect of elevated temperatures on the strength and stiffness properties of four reinforcing and three prestressing steels of varying size, manufactured to British Standard specifications, has been investigated. To simulate the temperatures likely to be experienced by the steel during a fire, a temperature range of 20° to 700° was adopted. The steels were tested in their 'as manufactured' condition in a purpose-built, tensile testing machine with tube furnaces and associated recording instrumentation. The test programme was designed to provide data on three major strength parameters-yield (or 0.2 % proof) stress, ultimate strength, and elastic modulus. Using the datu it is possible to assess the deterioration in strength of a structure during a fire and its residual strength at ambient temperature after a fire. M. Holmes, R.D. Anchor, G.M.E. Cook and R.N. Crook

Price – £10
The Structural Engineer
<h4>Natural Frequencies of Frames With Inclined Rafters</h4>

Natural Frequencies of Frames With Inclined Rafters

The pitched roof portal building is of considerable economic importance in industry, and it is sometimes necessary to calculate natural frequencies of vibration to determine the response of such structures to vibrating machinery or to environmental forces such as dynamic wind forces. Professor A. Bolton

Price – £10