Our review of a U.S. Government report under this title describing the various new forms of metal connectors that have developed for purposes of timber framework construction on the European continent appeared on page 362 of the Journal for August, 1933. We now reproduce a photograph of such connectors (Figure 1) and two examples of their use.

Additional information

Format:
PDF
Publisher:
The Institution of Structural Engineers

Tags

Issue 2

Related Resources & Events

The Structural Engineer
<h4>Water Ratio Rules and their Limitations</h4>

Water Ratio Rules and their Limitations

WATER ratio rules appear to afford a simple method of controlling the strength of concrete. It is true that the application of such rules in practice is complicated by the necessity for allowances for the absorptions of the aggregates or for the free water which may be present in them, but this may be regarded as a legitimate problem for the engineer in charge. The real difficulty lies in the fact that strength is also affected by other factors relating to the composition of the concrete, and, in the brief introductory account which follows, methods of making allowance for the effects of these factors are mentioned. W. Hunter

Author – Hunter, W
Price – £10
The Structural Engineer
<h4>The Constructional Aspect of Large Electricity Generating Stations</h4>

The Constructional Aspect of Large Electricity Generating Stations

The constructional side of large electricity generating stations is a subject which has perhaps not received the consideration it deserves. This appears somewhat surprising when it is realised that the cost of the building works only of a large modern power station, excluding coal and ash handling facilities, condensing water system, and external subsidiaries, may be a proportion of the order of some 20 per cent. to 25 per cent. of the total cost of the station completely equipped with plant. Arthur Creswell Dean

Author – Dean, Arthur Creswell
Price – £10
The Structural Engineer
<h4>Rigid Frame Bridges in Reinforced Concrete. Discussion on Mr. A.P. Mason's Paper</h4>

Rigid Frame Bridges in Reinforced Concrete. Discussion on Mr. A.P. Mason's Paper

Mr. M. N. RIDLEY, M.Inst.C.E. (Member of Council), proposing a vote of thanks to the author, welcomed the paper, particularly because it indicated the extent to which continuity in reinforced concrete work was being adopted. He had noticed that engineers were inclined to make pin joints in their bridges. They would put a pin joint in the centre of the arch and pin joints in the abutments, and he believed that in one or two cases there were as many as five. He had always maintained, however, that. a bridge of ordinary span was far safer and better, and sometimes more economically designed, if all pin joints were excluded. It was true that calculation was then more difficult, but he held that when that had been done one had the best type of work. Where there were very big spans, of course, one must consider pin joints or the equivalent, especially for expansion and contraction; but for shorter spans, at any rate up to 100 ft. and sometimes more, in reinforced concrete and steel work pin joints were quite unnecessary.